Description:
How can an MRI cause a burn when nothing hot is touching you—and can it happen without any metal involved?

MRI safety expert Tobias Gilk explains the science behind MRI burns in this stand-alone “Geeking-Out Segue” from The Invisible Force. Discover how radiofrequency (RF) energy produces heating inside the body, and why energy spread across a large area can have a very different effect when concentrated in one small spot.

What changes when a wire or implant is present? Why can clothing, skin-to-skin contact, or proximity to the scanner wall matter? And why can’t we rely on patients to feel a burn before injury occurs?

Through everyday comparisons and straightforward explanations, this episode connects RF heating with the positioning, padding, screening, and communication practices that help protect patients.

It also sets the stage for the upcoming season’s investigation of an MRI burn—giving you the background to understand how the injury could happen and the safety questions it raises.

New to The Invisible Force? Start here. No physics degree or previous episodes required. Follow the show for the story ahead.

Transcript:
“I’ve heard about MRI-related burns. How can an MRI burn you? The inside of the scanner doesn’t get hot, does it?”

Hello and welcome to a new episodic feature of The Invisible Force, the Geeking-Out Segue. These episodes are not part of our story-based series, but are interjected, stand-alone episodes that help provide some context or explanation. They might be helpful if you want a deeper dive into the subject matter that our stories cover.

Sometimes these segues will be on science, sometimes they’ll be about healthcare operations, and sometimes they’ll be on regulatory issues. But they’re always going to be supplemental to the main stories. This Geeking-Out Segue is specifically about how MRI exams produce heating, and how that heating can concentrate and result in patient burns. And no, the inside of the scanner shouldn’t ever get hot. But you might feel hot while you’re in there. Let’s explore that.

In MRI, in order to generate imaging information, we transmit oscillating magnetic field energy at the body of our MRI patients. Some of that transmitted energy is momentarily held by the atoms and molecules in the patient’s body and is released again. These released signals, they behave differently depending on the molecular environment that they’re in. Those differences help the scanner distinguish different tissues. The MRI system reads these millions of tiny little signals, and with a good deal of computing power, the MRI organizes them into what ultimately become a set of pictures for the radiologist to read. However, much of the energy transmitted into the MRI patient’s body doesn’t turn into signal. It turns into heat.

“But how does a magnetic field turn into heat?”

Magnetic field energy isn’t heat, at least not to start. But when you have a pulsed or oscillating magnetic field, you also create, through a scientific principle called Faraday’s Law of Induction, an induced electrical current. The more conductive the material is, the more electrical current a changing magnetic field can generate. But in addition to inducing current, different material properties allow the magnetic field to concentrate the electrical energy certain ways that can also increase resistive heating.

If you like to watch competition cooking shows, or if you have a fancy new stove in your home, you may have seen induction burner cooktops. One of the most astounding things about induction cooktops is that without a pan on top, the surface stays at room temperature even when it’s turned up to high. This is because unlike gas burners or electric resistance heaters, they don’t create heat. They create an oscillating magnetic field which generates heat in the pan sitting on them. Yes, the cooktop can become warm from being in contact with a hot pan, but the heat comes from the pan, not from the cooktop.

“Okay, but I’m not a frying pan. Why would that happen to me?”

Throughout our bodies are ionic fluids such as our blood. That means that even if we’re not a frying pan, we’re at least somewhat electrically conductive. But the difference between us and a frying pan are pretty important when it comes to heating risks. Inductive heating of different materials has to do with A, how much current can be developed in that material, B, if the material can be magnetized to concentrate the flow of electrical current in certain areas, and C, how much resistance to the flow of electricity occurs in that material.

Ultimately, as the electrical energy that is created in the material, whether that material is a frying pan or you as the MRI patient, that electrical energy, as it travels, it experiences electrical resistance, which turns it into another form of energy, heat. Thankfully, the makeup of our bodies helps inhibit the amount of this heating that we can experience as MRI patients.

“If the scanner puts energy into my body, what stops me from overheating?”

First and foremost, MRI scanners limit the amount of magnetic field energy that is principally responsible for heating to levels that ought to be safe. MRI patients’ bodies generally wind up experiencing low-level warming in the body parts being exposed to the MRI’s transmitted radio frequency or RF energies. However, because our bodies balance heat distribution really well, that warming winds up getting shared throughout an MRI patient’s whole body. All other things being equal, you’re expected to warm up during an MRI study.

Like being outside on a hot summer day or working out at the gym, faster breathing, sweating and getting flush are all ways that your body helps get rid of the excess heat. Burning sensations, those aren’t supposed to be part of an MRI exam.

“Then how can one small spot burn while the rest of me barely warms up?”

There are things that can drastically change the quantity of energy you’re exposed to in one area or the efficiency of the energy transfer. As just one example, there are hot spot regions behind the white plastic wall of the MRI tubes where if you’re too close for too long, you could develop a burn. These types of burns are often referred to as near-field effect or proximity burns. On some systems, the manufacturer specifies separation measured in just millimeters. That’s why the correct padding that meets the manufacturer’s minimum specifications and keeping it properly positioned, that’s why that matters so much.

“Why should being just a little bit closer to the scanner wall make a difference?”

Little distances can make big differences. If you’ve ever hung out next to a bonfire on a cold night, there’s a magical distance that makes you feel comfortable. Just a few inches too close and the front of you becomes uncomfortably hot. The general principle applies here, too, but the physical scales of the bonfire and the radio frequency heating proximity are very different.

In MRI, maintaining the manufacturer-indicated minimum separation, even if that separation is only a handful of millimeters, that’s crucial to preventing this one type of burn.

“What changes if there’s a wire or something metal in there with me?”

That’s when things can get potentially very dangerous. The amount of induced electrical current is, in part, based on how good of an electrical conductor that’s there. But we can’t just look at something and know, because there are metal things out there that don’t really look like metal.

One example, if you’ve ever seen an anti-microbial or an anti-odor treated t-shirt or underwear or workout clothes, many of these fabrics are treated with nanoparticle silver or copper, both really electrically conductive metals. So your workout outfit or yoga pants, they could have enough metal in that treatment that parts of them could start acting like a wire. This is one of the main reasons that hospitals and imaging centers increasingly have patients change out of their street clothes into hospital gowns or scrubs.

When there’s a really good conductor, in other words, metal, especially if it’s in an electrically insulated conductor like a pacemaker lead, that limits where the electrical current can escape into the surrounding tissues. A couple of things can happen in this situation. First, the wire itself can heat up. Even when that doesn’t happen, where the wire’s insulation stops, that induced electrical current that got induced into the wire, it bleeds out into the patient’s tissues at the location where insulation is stopped or is broken. Tissues aren’t nearly as good at conducting electricity as the wire is. With more electrical resistance in the patient’s tissue comes greater conversion of that electrical energy into thermal energy and can result in a focused burn.

There are implants, including certain types of pacemaker leads, that are specifically engineered to reduce these risks. But without knowing a specific type or its specific labeling for MRI safety, MRI providers are generally going to be very cautious and remove anything that can be removed such as EKG wires before an MRI exam. Unless they can verify that this specific product has the MRI safety designation, MR conditional, and that the conditions for safe use can be met.

“Could I get burned even if there’s no metal involved?”

Yes. Whether it’s getting your body too close to the transmitters behind the wall of the tube, or even making skin-to-skin contact creating large loops of your own body such as your thumb touching the outside of your thigh, there are ways that burns can happen without anything metal. The good news is that the types of burns that happen without any metal, when it’s just the patient’s body, those types of burns are overwhelmingly preventable through effective patient preparation, positioning and padding.

“So, which precautions actually interrupt that process?”

Apart from getting rid of any extra metal, changing out of your street clothes, making sure that there’s an appropriate air gap or padding between the patient and the wall of the tube, and making sure that there are pads that separate your arms from your sides, or your thighs or calves from touching one another. Whichever parts of your body are inside the tube during the MRI scan. These can almost entirely eliminate the possibility of these sorts of burns.

“And give patients the squeeze ball, right?”

Actually, that’s not always an effective means of preventing MRI-related burns. We’re still learning about them, but for several types of MRI burns, they appear to originate in parts of our body where there aren’t temperature or pain-sensing nerves. In other words, you could be fully awake and alert with the squeeze ball in your hand, but being burned, and be completely unaware of it in the moment. Squeeze balls aren’t really universal preventative tools, not for all patients and not for all risks. They obviously can’t help when the patient is asleep or unable to squeeze it, and it won’t help prevent all types of MRI burns even when the patient is awake and can squeeze the squeeze ball.

The takeaway, use the squeeze ball for unexpected heating and for other communication needs, but we should never depend on the patient feeling a burn before an injury occurs.

Just remember that MR imaging uses oscillating magnetic fields, and that those fields create electrical currents in both not-so-great electric conductors, like inside our human bodies, and in good electrical conductors, such as metals, especially insulated leads or wires. Those electrical energies, they’re going to flow until they encounter resistance, and that resistance converts the electrical energy into heat. If it happens gently, all over, a patient will get warm. If that happens concentrated in one place, or in one electrically conductive object, a burn can result.

Podcast also available on PocketCasts, SoundCloud, Spotify, Google Podcasts, Apple Podcasts, and RSS.

Leave a Reply

Your email address will not be published. Required fields are marked *

The Podcast

Join co-hosts John Posh and Tobias Gilk who together have about 60-years of MRI and MRI safety experience between them (boy that makes them sound old) for a podcast about MRI accidents and how we can protect ourselves (and those we love) from preventable accidents in MRI.

About the podcast